Feedback (2)

Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs for 8 Butterfly Valve, Sewer Check Valve, Pipe Ball Valve, We are also the appointed OEM factory for several worlds' famous products brands. Welcome to contact us for further negotiation and cooperation.
Best Sump Pump Shut Off Valve Manufacturers – Fluorine-lined stainless steel/cast steel national standard diaphragm valve – JUGAO VALVE Detail:

Product Description

How does a Diaphragm Pump Work?
Air double diaphragm pumps utilize two flexible diaphragms that reciprocate back and forth to form a temporary chamber that sucks in and out fluid through the pump. The diaphragms act as a wall of separation between the air and the fluid.

main6

The specific operating principle is as follows:
The first stroke
Is through the center section where the air valve is located, with two diaphragms connected by a shaft. The air valve serves to direct compressed air behind diaphragm No.1, away from the center section. The first diaphragm causes a pressure stroke to move the fluid out of the pump. At the same time, diaphragm No.2 is undergoing a suction stroke. The air behind diaphragm No.2 is pushed into the atmosphere, causing atmospheric pressure to push the fluid to the suction side. The suction ball valve is pushed off its seat, allowing fluid to flow through it into the liquid chamber.
Second stroke
When pressurized diaphragm No.1 reaches the end of its stroke, the movement of air is switched by the air valve from diaphragm No.1 to the back of diaphragm No.2. The compressed air pushes diaphragm No.2 away from the center block, causing diaphragm No.1 to be pulled toward the center block. In pump chamber two, the discharge ball valve is pushed away from the seat, while in pump chamber one, the opposite occurs. After the stroke is complete, the air valve directs the air to the back of diaphragm No.1 again and restarts the cycle.

Product features

What Is A Diaphragm Pump Used For?
Conveying fluids:
• Corrosive chemical
• Volatile solvents
• Viscous, sticky fluids
• Shear-sensitive foodstuffs and pharma product
• Dirty water and abrasive slurry
• Smaller solids
• Creams, gels and oils
• Paints
• Varnishes
• Greases
• Adhesives
• Latex
• Titanium dioxide
• Powders

main1
main4

Application scenarios:
• Powder Coating
• General Transfer/Unloading
• Air Spray – Transfer or Supply
• Drum Transfer
• Filter Press
• Pigment Milling
• Paint Filtration
• Filling Machines
• Mixer Tanks
• Waste Water Discharge

Ball Valve Pump VS Flap Valve Pump
Double diaphragm pumps may have ball or disc valves, depending on the type, composition, and behavior of solids in the pumped fluid. These valves operate by utilizing pressure differences in the pumped fluid.
Flap valve is most suitable for large solid (pipe size) or paste containing solids. Ball valves perform best when handling settling, floating or suspended solids.
Another obvious difference between ball valve pumps and flapper pumps is the intake and discharge ports. In ball valve pumps, the suction inlet is located at the bottom of the pump. In flapper pumps, the intake is located at the top, allowing it to handle solids better.

main5
main2

Why Choose An AODD Pump?
Pneumatic diaphragm pump is a versatile mechanical device that enables users to standardize on a single pump type to handle a wide variety of fluids in different industries. As long as there is a compressed air supply, the pump can be installed wherever it is needed, and it can be moved around the plant and easily switched to other operations if conditions change. Whether it is a fluid that needs to be pumped slowly, or a positive displacement AODD pump that is chemically or physically aggressive, it provides an efficient, low maintenance solution.
For Further Questions Please Contact Us
Do you want to know how a pump can help your process control? Leave your contact information and one of our pump experts will get in touch with you!


Product detail pictures:

Best Sump Pump Shut Off Valve Manufacturers –  Fluorine-lined stainless steel/cast steel national standard diaphragm valve – JUGAO VALVE detail pictures

Best Sump Pump Shut Off Valve Manufacturers –  Fluorine-lined stainless steel/cast steel national standard diaphragm valve – JUGAO VALVE detail pictures

Best Sump Pump Shut Off Valve Manufacturers –  Fluorine-lined stainless steel/cast steel national standard diaphragm valve – JUGAO VALVE detail pictures

Best Sump Pump Shut Off Valve Manufacturers –  Fluorine-lined stainless steel/cast steel national standard diaphragm valve – JUGAO VALVE detail pictures

Best Sump Pump Shut Off Valve Manufacturers –  Fluorine-lined stainless steel/cast steel national standard diaphragm valve – JUGAO VALVE detail pictures


Related Product Guide:

We believe in: Innovation is our soul and spirit. High-quality is our life. Consumer need to have is our God for Best Sump Pump Shut Off Valve Manufacturers – Fluorine-lined stainless steel/cast steel national standard diaphragm valve – JUGAO VALVE, The product will supply to all over the world, such as: Florida, Haiti, Denver, We pay high attention to customer service, and cherish every customer. We have maintained a strong reputation in the industry for many years. We are honest and work on building a long-term relationship with our customers.
  • The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Lillian from Australia - 2017.01.28 19:59
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Sarah from United Arab emirates - 2018.12.14 15:26